Forced circulation evaporator manufacturer since 2000 · ISO 9001:2015 certifiedFor liquids that scale, crystallize or thickenDesign, supply, installation and maintenance from one team

Forced CirculationEvaporators by Acmefil

Forced Circulation Evaporator Services

Process study, design, supply, commissioning and maintenance from one engineering team.

  • 24+Years of engineering
  • 7steps round the circulation loop
  • 5evaporator types we build and compare
  • ISO9001:2015 certified

What we do

Everything around your evaporator

Study, selection, design, supply, commissioning and service – from one team.

Process study & selection

Chosen on your liquid, your target concentration and your utilities – confirmed on your data.

Design, engineering & supply

Process design, mechanical design and manufacture in our Vatva works.

Installation, commissioning & training

Our own erection team, start-up and operator training at your site.

Complete plants

Evaporator, condenser, vacuum system, pumps and controls – up to a zero liquid discharge plant.

Automation & control

PLC / SCADA with interlocks, trends and alarms.

Upgrades, rebuilds & AMC

Capacity upgrades, retrofits, genuine spares and annual maintenance.

How we work

From the first study to the last spare part

One team takes your project through six steps.

  1. 1

    Understand your liquid

    Feed concentration, solids, scaling and crystallizing behaviour, viscosity, heat sensitivity and the target concentration.

  2. 2

    Select the evaporator

    Forced circulation alone, with a falling film pre-concentrator, as a multi-effect plant or with an ATFD, with the reasons.

  3. 3

    Design

    Process and mechanical design tailored to your liquid and your utilities.

  4. 4

    Supply

    Heater, separator, circulation pump, condenser, vacuum system and controls.

  5. 5

    Install & commission

    Our own erection and commissioning team starts the plant and trains your operators.

  6. 6

    Maintain & support

    Genuine spares, upgrades, rebuilds and annual maintenance contracts.

Multi-effect evaporator: live steam heats the first effect, and the vapor from each effect heats the next one, which runs at lower pressureEffect 1Effect 2Effect 3FeedLive steamVapor heats the next effectConcentrateCondenserVacuumCondensate
FeedSteamVaporConcentrate

Start with your liquid

A process study before you invest

Send us the liquid, the feed and target concentration and the flow. We come back with the evaporator we recommend, the reasons, the alternatives we ruled out and a budget quote.

  • A recommendation on forced circulation or the alternative, with the reasoning
  • A budget quote and the scope we propose
  • The information we still need from your process

Selection guide

Eight things that decide the evaporator

Know these before you ask for a quote – they are what our engineers ask first.

Feed and concentrate

The feed concentration and the concentration you need set how much water has to be evaporated per hour – the real size of the plant.

Scaling and crystallizing

The main reason to choose forced circulation. Salts, hardness or a product that crystallizes would foul a film evaporator; high liquid velocity keeps the tubes clean.

Viscosity and solids

Thick liquids and slurries do not form a good film. The pump keeps them moving through the heater, so forced circulation handles higher viscosity.

Heat sensitivity

Colour, flavour or activity at risk? Vacuum lowers the boiling temperature, and a falling film pre-concentrator can do the first part gently.

Crystals or a clear concentrate

Do you want crystals out, or a concentrated liquid? Crystallizing duties need a separator and a slurry draw-off sized for the crystals.

Steam and energy

On large duties steam dominates the running cost. Forced circulation effects can run in a multi-effect plant to reuse the vapor.

Utilities

Steam or hot water, cooling water, vacuum and power – each changes the layout and the running cost.

Materials of construction

Chlorides, acids and abrasive crystals decide the alloy of the tubes, separator and pump. Effluent and brine often need higher alloys.

Services

From the first study to the last spare part

  • Process study and evaporator selection
  • Design, engineering, supply and support
  • Installation, commissioning and training
  • Complete plants with user-friendly design
  • Condensers, vacuum systems and effluent treatment
  • Free technical support for troubleshooting
  • Plant upgrades and rebuilds
  • Plant automation and control
  • Genuine spares and maintenance
  • After-sales service
  • Annual maintenance contracts

Free proposal

Tell us about your liquid. We will size the forced circulation evaporator.

Share the liquid, the feed and target concentration and the flow. Get a recommendation and a budget quote within one working day.

Secure form · we never share your details · reply within one working day

Call WhatsApp Get a Quote